                                             Quick Installation Guide - DDP-2
               To install the unit, create a cut-out in your countertop following the dimensions
                                    given on the drawing and the table below.
            This cooktop must be installed in
            accordance with pertaining local
            building, trade, fire protection and
            electrical codes. If local codes do
            not exist, then installation must be
            done in accordance with federal
            codes.

            The cooktop is to be connected -
            hard-wired - to the electrical power
            supply inside a client-supplied
            junction box which should be
            installed inside the cabinet below the
            unit. The unit must be properly
            grounded.

            This cooktop is to be installed under
            a ventilation hood or a downdraft                                      Cooktop and
            ventilation system.                                                                               Width           Depth         Thickness
                                                                                   Cut-out Sizes
            DDP-2 Electrical Characteristics are:                                 Cut-out Size               270 mm         496 mm          142 mm*
                                                                                                             [10 5/8"]      [19 1/2"]        [5 5/8"]*
            Operating Voltage                   ... 240 V~ 60 Hz
                                                                                  Cooktop Box Size            263 mm        490 mm            92 mm
            Max. Power Output                   ... 3600 W                                                   [10 3/8"]      [19 1/4"]        [3 5/8"]
                                                                                  Cooktop Rim Size            310 mm         518 mm           10 mm
            Connect to             ... 240 V, 60 Hz, 2 Pole+G,                                              [12 3/16"]      [20 3/8"]        [25/64"]
                                        20 A supply                               *This dimension includes clearance underneath the unit of 50 mm [2"]
                                       (3-wire #12 AWG)


                 Cabinet Above                                 Clearance

                                            Cross              You should keep:
                                           Section
                             750 [30"]




                                                                      - In the back of your unit - between the unit and any
                                                                      vertical surface: minimum clearance of 10 mm (3/8");

                                           Minimum                    - If a downdraft ventilation system is used - between the
                 10 [3/8"]
                                          Clearance                   unit and the downdraft snorkel: minimum clearance of
                                         Requirements                 6 mm (1/4");
                   Exhaust

                                                                      - Above the unit to any combustible surface - e.g. cabinet
                        DDP-2                                         above the unit: minimum clearance of 750 mm (30");
                                                     50 [2"]




                 Air                                                  - Below the unit - between the bottom of the unit and any
               Intake   Cabinet Below                                 horizontal partition inside your cabinet: minimum clearance
                                                                      of 50 mm (2").