Quick Installation Guide - DDP-4
To install the unit, create a cut-out in your countertop following the dimensions
given on the drawing and the table below.
This cooktop must be installed in
accordance with pertaining local
building, trade, fire protection and
electrical codes. If local codes do
not exist, then installation must
be done in accordance with
federal codes.
The cooktop is to be connected -
hard-wired - to the electrical power
supply inside a client-supplied
junction box which should be
installed inside the cabinet below the
unit.
The unit must be properly
grounded.
This cooktop is to be installed under
a ventilation hood or a downdraft
ventilation system.
Cooktop and Width Depth Thickness
DDP-4 electrical characteristics are: Cut-out Sizes
Operating voltage ... 240 V~ 60 Hz Cut-out Size 750 mm 496 mm 142 mm*
Total power ... 7200 W [29 1/2"] [19 1/2"] [5 5/8"]*
Cooktop Box Size 743 mm 488 mm 92 mm
Connect to ... 240 V, 60 Hz, 2 Pole+G,
[29 1/4"] [19 7/32"] [3 5/8"]
40 A supply Cooktop Rim Size 790 mm 518 mm 10 mm
(3 wire #8 AWG) [31 1/8"] [20 3/8"] [25/64"]
*This dimension includes clearance underneath the unit of 50 mm [2"]
Cabinet Above Clearance
Cross You should keep:
Section
750 [30"]
- In the back of your unit - between the unit and any
vertical surface: minimum clearance of 10 mm (3/8");
Minimum - If a downdraft ventilation system is used - between the
10 [3/8"]
Clearance unit and the downdraft snorkel: minimum clearance of
Requirements 6 mm (1/4");
Exhaust
- Above the unit to any combustible surface - e.g. cabinet
DDP-4
50 [2"]
above the unit: minimum clearance of 750 mm (30");
Air
Intake
- Below the unit - between the bottom of the unit and any
Cabinet Below
horizontal partition inside your cabinet: minimum clearance
of 50 mm (2").