Quick Installation Guide - DDP-5
To install the unit, create a cut-out in your countertop following the dimensions given on the
drawing and the table below.
This cooktop must be installed in
accordance with pertaining local
building, trade, fire protection
and electrical codes. If local
codes do not exist then installa-
tion must be done in
accordance with federal codes.
The cooktop is to be connected -
hard-wired - to the electrical power
supply inside a client-supplied
junction box which should be
installed inside the cabinet below
the unit. The unit must be
properly grounded.
This cooktop is to be installed
under a ventilation hood or a
downdraft ventilation system.
Cooktop electrical characteristics are: Cooktop and Width Depth Thickness
Operating voltage ... 240 V ~ 60 Hz Cut-out Sizes
Total power ............ 9600 W Cut-out Size 900 mm 496 mm 142 mm*
Connect to .... 240 V, 60 Hz, 2 Pole+G [35 7/16"] [19 1/2"] [5 5/8"]*
50 A (min) supply Cooktop Box Size 893 mm 488 mm 92 mm
(3-wire #8 AWG) [35 5/32"] [19 7/32"] [3 5/8"]
Cooktop Rim Size 938 mm 518 mm 10 mm
[36 15/16"] [20 3/8"] [25/64"]
*This dimension includes clearance underneath the unit of 50 mm [2"]
Clearance
Cabinet Above
You should keep:
Cross
Section
- In the back of your unit - between the unit and any
750 [30"]
vertical surface: minimum clearance of 10 mm (3/8");
Minimum - If a downdraft ventilation system is used - between the
10 [3/8"]
Clearance unit and the downdraft snorkel: minimum clearance of
Requirements 6 mm (1/4");
Exhaust
- Above the unit to any combustible surface - e.g. cabinet
DDP-5 above the unit: minimum clearance of 750 mm (30");
50 [2"]
- Below the unit - between the bottom of the unit and any
DDP 03/06
Air
Intake Cabinet Below horizontal partition inside your cabinet: minimum clearance
of 50 mm (2").