Information about http://www.ajmadison.com/ajmadison/itemdocs/Install_DDP5_B.pdf

Pages: 1
Language: english
Created: Mon Mar 20 17:01:01 2006
Display cached document
Page 1
image
                                                                   Approved by:                                Diva de Provence
                                                                                                         885 Don Mills Road, Suite 207
                                                                                                                Toronto,Ontario
                                                                                                                    M3C 1V9
                                                                                                                   Canada
                                                                                                              Tel: (416) 256-2646
                                                                                                              Fax: (416) 256-7121


                                              Quick Installation Guide - DDP-5
            To install the unit, create a cut-out in your countertop following the dimensions given on the
                                              drawing and the table below.
                                                                                                          This cooktop must be installed in
                                                                                                          accordance with pertaining local
                                                                                                          building, trade, fire protection
                                                                                                          and electrical codes. If local
                                                                                                          codes do not exist then installa-
                                                                                                          tion    must     be   done     in
                                                                                                          accordance with federal codes.

                                                                                                          The cooktop is to be connected -
                                                                                                          hard-wired - to the electrical power
                                                                                                          supply inside a client-supplied
                                                                                                          junction box which should be
                                                                                                          installed inside the cabinet below
                                                                                                          the unit.     The unit must be
                                                                                                          properly grounded.

                                                                                                          This cooktop is to be installed
                                                                                                          under a    ventilation hood or a
                                                                                                          downdraft ventilation system.

            Cooktop electrical characteristics are:                                Cooktop and                Width           Depth         Thickness
             Operating voltage ... 240 V ~ 60 Hz                                   Cut-out Sizes
             Total power ............ 9600 W                                      Cut-out Size               900 mm      496 mm             142 mm*
             Connect to .... 240 V, 60 Hz, 2 Pole+G                                                         [35 7/16"]   [19 1/2"]          [5 5/8"]*
                                50 A (min) supply                                 Cooktop Box Size           893 mm      488 mm              92 mm
                                (3-wire #8 AWG)                                                             [35 5/32"]  [19 7/32"]          [3 5/8"]
                                                                                  Cooktop Rim Size            938 mm      518 mm             10 mm
                                                                                                            [36 15/16"] [20 3/8"]           [25/64"]

                                                                                  *This dimension includes clearance underneath the unit of 50 mm [2"]

                                                                Clearance
                  Cabinet Above

                                                                You should keep:
                                             Cross
                                            Section
                                                                       - In the back of your unit - between the unit and any
                              750 [30"]




                                                                       vertical surface: minimum clearance of 10 mm (3/8");

                                            Minimum                    - If a downdraft ventilation system is used - between the
                  10 [3/8"]
                                           Clearance                   unit and the downdraft snorkel: minimum clearance of
                                          Requirements                 6 mm (1/4");
                    Exhaust

                                                                       - Above the unit to any combustible surface - e.g. cabinet
                         DDP-5                                         above the unit: minimum clearance of 750 mm (30");
                                                      50 [2"]




                                                                       - Below the unit - between the bottom of the unit and any
DDP 03/06




                  Air
                Intake   Cabinet Below                                 horizontal partition inside your cabinet: minimum clearance
                                                                       of 50 mm (2").